Comparison of performance of digital hemoglobinometer over automated hematology analyzer for hemoglobin estimation and its user-friendliness among the pregnant women in selected district hospitals of Madhya Pradesh


1 Department of Community Medicine, Gandhi Medical College, Bhopal, Madhya Pradesh, India
2 Department of Community Medicine, AIIMS, Raipur, Chhattisgarh, India
3 Maternal and Child Health, NHM, Government of MP, Madhya Pradesh, India

Correspondence Address:
Dr. Devendra Gour
Department of Community Medicine, Gandhi Medical College, Bhopal, Madhya Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijcm.IJCM_216_18

Rights and Permissions

Context: There is a need for a simple screening method for the detection of anemia that can be used by public health workers in the field. Aims: The aim of this study was to compare two methods for hemoglobin estimation, i.e., automated hematology analyzer and Digital Hemoglobinometer, and to find out the sensitivity and specificity of Digital Hemoglobinometer for the estimation of hemoglobin. Subjects and Methods: A hospital-based cross-sectional study was carried out for 6 months from April to September 2017 in a District Hospital of five High Priority Districts of Madhya Pradesh. Two hundred and sixty antenatal females per district were selected for the study. Results: The mean hemoglobin by autoanalyzer is 10.19, and that by Digital Hemoglobinometer device is 9.89. Overall, sensitivity of Digital Hemoglobinometer for hemoglobin estimation was calculated to be 89.4% and specificity was calculated to be 63.6%. Positive predictive value was found to be 82.6% and negative predictive value was 75.8% compared against AutoAnalyser (gold standard). Conclusions: As the Digital Hemoglobinometer device has high sensitivity and specificity and good diagnostic accuracy, it must be used at the community level in resource-poor setting for hemoglobin estimation. In primary health-care conditions, Digital Hemoglobinometer can significantly reduce misdiagnosis of anemia compared with clinical assessment alone.


[FULL TEXT] [PDF]*
Print this article  Email this article
    

  Similar in PUBMED
    Search Pubmed for
    Search in Google Scholar for
  Related articles
   Citation Manager
  Access Statistics
   Reader Comments
   Email Alert *
   Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1038    
    Printed13    
    Emailed0    
    PDF Downloaded110    
    Comments [Add]    

Recommend this journal

 

  Sitemap | What's New | Feedback | Copyright and Disclaimer
  2007 - Indian Journal of Community Medicine | Published by Wolters Kluwer - Medknow
  Online since 15th September, 2007